Is there any glaring difference that should sway me to use one over the. The low profile, half height card has 8 ports and utilizes ddr2800 memory. Tech support scams are an industrywide issue where scammers trick you into paying for unnecessary technical support services. Hp smart array p410256mb controller storage controller raid sata150 sas low profile 300 mbps raid 0, 1, 5, 10, 50 pci express x8 smart array p410256mb pcie2 int only manufacturer part number 462862b21. Smart array p440ar, sas to hp 18 g2 tape autoloader, raid1 and 10. As expected hp smart array p410i is not supporting raid6 and it is not transparent to operating system i. You can have monitoring and fan speed problems with random sata disks on that controller.
This will install the hp array drivers in preference to the supplied ones with whs 2011. P410i smart array controller sata drive recommendations of. After the os had installed, i then updated the p410 smart array controller drivers. Replacing hp p410 with p420 and keeping the data hi. Array p410 smart array p410i smart array p411 smart array p812 smart array p712m. Hp p410 raid smart array controller card anandtech forums. By clicking create account, you agree to the companys.
Component for windows smart array p212, p410, p410i, p411, p712m, and p812. I boot from the hp smart start cd to enter the hp array config utility when i needed to configuremaintain the cardarrays. Raid5 is available on the sa p410p410i with a minimum of 256mb cache and battery. Hpe does supply binary rpms and driver diskettes for loading drivers during os. Download hp smart array p410 controller controller drivers or install driverpack solution software for driver update. Other than that they are both identical in terms of electronic components, features and performance. How to swicth hp proliant gen8 p420i smart array controller to hda mode. Hp smart array p410512 bbwc 2ports int pcie x8 sas controller. Hp smart array p410i controller raid configuration it blog ixnfo. Hewlettpackard company smart array p410 kernel driver in use. Driver for hp smart array p400 controller for windows server 2012 can be downloaded from here.
Release device driver s firmware version additional firmware version type features. Get hp hp smart array p410i controller hp smart array controller technology, 4th edition. These older boards have not been tested and are not supported with hpsa, and cciss4. I cannot configure the raid on my p410i, and the only reason i can imagine 7330799. Raid 5 is available on the sa p410 p410i only if the 256mb and battery kit option is used. May 19, 2018 how to swicth hp proliant gen8 p420i smart array controller to hda mode. Hp proliant smart array sassata controller driver for windows server 2012. P410i smart array controller sata drive recommendations of known. I have over 75tb of data and not much extra cash to drum up a proper solution.
I have hp microserver n54l, until recently i have used integrated software raid without problems. My intention is just to check firmware versions available and compare. This configuration guide will walk you through the process of setting up a raid array on your hp p410p410i. Linux debian server work with hp smart array raid controller. Access product support documents and manuals, download drivers by operating environment, and view product support videos and. P410i smart array controller sata drive recommendations of known working models. Aug 21, 20 driver for hp smart array p400 controller for windows server 2012 can be downloaded from here. Seamless upgrades from past generations and upgrades to next generation hpe high performance and high capacity sas smart array controllers. You can only use this method while a server is offline and it requires an hp smart array advanced pack saap license.
Just make sure youre on the latest smart array firmware and youre good to go. Configuring arrays on hp smart array controllers reference. Hp smart array p410i adding a disk vmware communities. Hp smart array p212, p410, p410i, p411, p711m, p712m, and p812 controller firmware versions. Hp smart array controllers for hp proliant servers user guide part number 469988005 february 2010 fifth edition.
The p410 is limited to a single raid level, and two logical drives. I entered configuration utility for the raid controller hp smart array p410i and removed all logical drives, as there is no need for a hardware raid if youre going to use zfs. Some software requires a valid warranty, current hewlett packard enterprise support contract, or a license fee. Slow power on and storage operations with the hp smart array p410i controller. The installation package will not allow you to install the driver automatically from setup, so i have extracted the driver first and updated the smart array p400 controller manually from device manager. Hp smart array p410 raid controller stops working after. Hi we have a number of new hp servers with the smart arrary p410 card controlling the hard disks we need to create a gold build for these we have no problems installing an os, xenapp, pvs client, etc but when we try to pxe boot the machine using the local hard disk. Hp smart array p212, p410,p411,p711m,p818 controllers not. The server boots and i can start up linux mint from usb, but when i tried. For registration procedures, see the configuring arrays for hp smart array controllers reference guide available on the.
Is there any glaring difference that should sway me to use one over the other. Jul 28, 2017 hp smart array p410i controller raid configuration it blog ixnfo. The hitachis cant be monitored by the p410i lacking compatible smart support. Discussion in raid controllers and host bus adapters. The hp smart array p410 is hp s pci express pcie 2. Langsame raid performance hp p410i controller administrator. Here is my experience with hp smartarray controllers with freenas. Hp smart array p410 controller hp smart array p410 256mb controller 462862b21 hp smart array p410 512mb with bbwc 462864b21 upgrade options optional upgrades 512mb bbwc 462967b21 battery kit upgrade note. Is there supposed to be a license number that needs to be added to make the card work. Hp smart array p812 controller onboard expander firmware was updated to version 3. Some software requires a valid warranty, current hewlett packard. Following up on this, i researched this some more and the issue is that vmware 4.
Hp smart array p410 raid controller stops working after falls. Hp smart array p410i drive expansion solutions experts. I was trying to install nas4free freebsd on a hp proliant dl380g7. Replacing hp p410 with p420 and keeping the data hi, yes, technically all smart array controllers are compatible and the data for the logical drive configuration is stored both on the hard disks and the smart array controller, so you can upgrade the controller in this way. Hp smart array px2x controller with hp smartcache enabled on boot volume could potentially encounter file corruption when booting the system if the supercap is not fully charged due to being replaced or being in a power down condition for several days example 7 days. Find the right hpe smart array controllers and smart host bus adapters for your company needs. You should also buy some cache memory for the p410i controller and not use the zero memory option. Also, the p410 and p410i was later upgraded via firmware to enhance features and capabilities, but it did so by making sacrifices in compatibility with nonhp hardware which is fine with hp, they dont sell their cards for nonhp servers. Replacing hp p410 with p420 and keeping the data hewlett. Once the smart array controller has initialized, pressing f9 allows you to configure the array before installing the os, which in my case is whs 2011. The p410 is a pcie card that you can add on to any pcie slot. Hp p410i w 512mb cache and sata drive servethehome and.
Im currently researching a 16 or 20 drive windows based storage server and am very interested in using the hp card for the. Hi i was wondering if anyone with any experience with a hp p410i smart array controller can help me. I have a question about hp p410 raid smart array controller card. Hp smart array controllers for hp proliant servers user guide.
Hdds will be visible to operating system only as logical devices after they are configured in controller. Smart array controllers and smart host bus adapters hpe. Features 7 for registration procedures, see the configuring arrays for hp smart array controllers reference guide available on the controller documentation cd or the acu product page on the hp website. Keep in mind that this is for my home and the data isnt mission. Raid controllers free delivery possible on eligible purchases. The p410p420 do have a fbwc option which is a different cache board completely. Problems with hp smart array p410 provisioning server. Trying to make a hp smartarray p410 work in a consumer. Smart array p212, p410, p410i, p411, p711m, p712m, and p812. Hp smart array p212,p410,p411,p711m,p818 controllers not. Hey guys, for my new fileserver, i bought the following hardware.
Hp smart array p410i controller raid configuration. Most viewed solutions for hp smart array p410i controller hp support center. Sep 21, 2012 i found on hp drivers for vmware esxi 5. Slow virtual machine storage when using hp smart array p410 with esx 3. The server boots and i can start up linux mint from usb, but when i. Also, the p410 and p410i was later upgraded via firmware to enhance features and capabilities, but it did so by making sacrifices in compatibility with non hp hardware which is fine with hp, they dont sell their cards for non hp servers. How to turn hp smart array raid controller to hba mode. So you choose either to have raid0, raid1 or 10 or raid5. Use hp sas disks with smart array p410 raid controllers. Trying to make a hp smartarray p410 work in a consumer grade. Firmware for hp smart array controllers and hp hba controllers. Smart array p410i in slot 0 embedded bus interface. The overall impression regarding building storage system on hp proliant dl380 g7 is miserable.
Hp smart array p410 controller hewlett packard enterprise. Raid 5 is available on the sa p410p410i only if the 256mb and battery kit option is used. Configuring arrays on hp smart array controllers reference guide. Linux debian hp smart array raid controller vps hosting. Apr 28, 2012 once the smart array controller has initialized, pressing f9 allows you to configure the array before installing the os, which in my case is whs 2011. Jan 27, 2016 then i go to this url to download latest firmware for hp smart array p410 also support for p212, p410i,p411,p711m,p712m,p812 hp smart array p212, p410, p410i, p411, p711m, p712m, and p812 controller firmware versions. I have 2x wd black and 2x wd red nonpro disks for my raid array. Hello all, havent had a whole lot of luck finding info on this, so asking here, to see what people have done.
Did hp ever make a driver for windows 2016 server using a p410i array controller. I purchased hp p410 with 256mb memory back with a battery back write cache module. The server has also a 2port p410i smart array controller integrated on the mainboard. Hp smart array p410 256mb controller storage controller raid sata150 sas low profile 300 mbps raid 0, 1, 5, 10, 50 pci express x8 smart array p410 256mb pcie2 int only manufacturer part number 462862b21. Hp 512mb pseries battery backed write cache upgrade.
I also have ssd directly on the motherboard not that it matters, just to get all facts straight. You can also use a manual method with any smart array controller. Hp smart array p212,p410,p411,p711m,p818 controllers not showing full size 3tb or above hdd. Hi, has anyone used a hp smart array p410 raid controller maybe even in combination with the hp sas expander card or considered it for a diy storage server project. Hp p410i raid controller terrible sequential write. Hp smart array p410i controller drivers for windows 10 x86. You can help protect yourself from scammers by verifying that the contact is a microsoft agent or microsoft employee and that the phone number is an official microsoft global customer service number.
Use of smart array products across multiple applications results in a much lower total cost of ownership tco than any other server storage raid product. From this url you can download latest or older version of firmware. Smart array p410i hewlett packard enterprise community. Pick up a hp p410 raid controller and find the hp raid setup below. By downloading, you agree to the terms and conditions of the hewlett packard enterprise software license agreement. Replacing the fbwc module on the p410 and p411 models. The installation package will not allow you to install the driver automatically from setup, so i have extracted the driver first and updated the smart array. The p410 and p410i are functionally equivalent, as mentioned by kissmyasthma above. Hp p410 raid smart array controller card anandtech. What i would do is epoxy a heatsinkfan onto those chips. Im currently researching a 16 or 20 drive windows based storage server.
The p410 p420 do have a fbwc option which is a different cache board completely. Joule has an hp p410 with 1g flash back cache smart array controller. Option rom configuration for arrays orcaa simple utility used mainly to configure the first logical drive in a new server before the operating system is loaded. Hp smart array p410 controller hp smart array p410256mb controller 462862b21 hp smart array p410512mb with bbwc 462864b21 upgrade options optional upgrades 512mb bbwc 462967b21 battery kit upgrade note. Install hp smart array p410i controller driver for windows 10 x86, or download driverpack solution software for automatic driver installation and update.
Search hpe support center drivers for hpe smart array p410. Utilities available for configuring an array to configure an array on an hp smart array controller, three utilities are available. I suspect you or your purchasing dept bought the cheapest model. Oct 20, 2017 tech support scams are an industrywide issue where scammers trick you into paying for unnecessary technical support services. The most current 20 version of the p410 quickspecs lists 4tb sata drives as supported. This configuration guide will walk you through the process of setting up a raid array on your hp p410 p410i.
Vib file is used to update the hpsa driver after the esxi 5. However, for different oses, different results show up. Shop and buy smart array controllers and smart host bus adapters from hewlett packard enterprise, view our categories, sort filter and refine to narrow your selection. Hpes innovative design and integration work of the smart array family of products creates end users value that is unmatched in the industry. Smart array controller model, firmware and number of hard drives installed. Im wondering what the largest hard drive supported by the smart array p410i is with sff drives. The first method uses the hp array configuration utility acu split mirror feature. Online rom flash component for windows smart array p212, p410, p410i, p411, and.